SR&ED technical support · Illustrative investigation
Can the seal hold without warping?
Technological uncertainty
The seal bonds, but the edge curls.
In this hypothetical case, a BC packaging manufacturer is developing a seal for a new recycled laminate. A single heat pulse bonds the inner layer but leaves the film curled. Available studies and supplier data cover different laminates. Could a longer pause between two pulses reduce the curl while keeping enough peel resistance for the package?
- Routine quality control
- Operators check production pouches against the existing seal specification.
- Investigation
- The team tests whether changing the pause alters edge lift and the force needed to peel the seal.
Experimental record
What changed on each roll?
Comoving could connect an AI agent to the manufacturer’s dated run sheets and operator notes. A calculator produces the group means. The agent’s job is to trace the draft explanation back to what the operators recorded. Here the release instruction reveals that changing the gap also changed the total time under the clamp. The technical lead checks the cited settings and decides what to test next.
Open the sample investigation record
- Trial 1 · Single pulse
- A 0.8-second pulse bonded the film but left a curled edge on specimens from all three rolls. This observation prompted the split-pulse trial.
- Trial 2 · Split pulse
- Cut ten specimens from each roll. Within each roll, assign five at random to each gap. Run all 30 in random order, sealing one specimen per cycle. Use the same starting jaw temperature, pulse power and clamp pressure. Release the clamp 0.2 seconds after the second pulse ends.
- Measurements
- After 24 hours at 23 °C and 50% relative humidity, place each specimen on the same face on a flat plate and measure its greatest edge lift. Cut one 15 mm strip from its seal. Grip both tails, leave the seal unsupported and pull at 250 mm/min. Record the peak force and where the strip separates.
| Roll | Edge lift (mm) | Peak peel force (N) |
|---|---|---|
| A | 3.1 → 1.4 | 6.2 → 6.1 |
| B | 2.8 → 1.3 | 6.0 → 6.1 |
| C | 3.0 → 3.1 | 6.3 → 6.3 |
With the longer-gap setting, mean edge lift was 1.7 mm lower on roll A and 1.5 mm lower on B. On C it was 0.1 mm higher. Every synthetic strip separated at its seal. The similar mean peak forces cannot establish acceptable strength or leak tightness. Set a minimum peel force before the next trial and test finished pouches for leaks separately.
The longer gap added 0.2 seconds under the clamp. In the next trial, cross both gaps with post-pulse holds of 0.2 and 0.4 seconds on additional rolls. A short gap with a long hold and a long gap with a short hold each give 1.3 seconds from the first pulse to release. That comparison tests whether edge lift changes when the extra 0.2 seconds with the heater off falls between the pulses or after the second pulse.
For comparable edge-lift measurements in the next trial, use specimens of the same dimensions, cut in the same direction relative to film travel, and keep the seal the same distance from the edge. Record film thickness and track jaw and interface temperatures through each cycle to investigate the cause of the curl.
Keep dated run sheets with the film lot, settings, measurements and reason for the next trial. For SR&ED, the CRA considers the technological advancement sought and how the team investigated the uncertainty. Routine quality control is excluded. Comoving coordinates tax and filing work with qualified partners where appropriate.
Measurement reference · ASTM F88/F88M, seal strength of flexible barrier materials
For background on film properties and sealing conditions, see Ilhan et al. (2021), Understanding the factors affecting the seal integrity in heat sealed flexible food packages: A review.
Canada Revenue Agency guidance · What work is eligible · Guide to Form T661
Inspect the readings from all 30 seals
These readings were constructed for the example. Each pair gives one specimen’s edge lift in millimetres and peak peel force in newtons. Average the five values for each measurement within a setting to reproduce the table.
- Roll A · 0.1 s
- (2.8, 6.0) · (3.3, 6.4) · (3.0, 6.2) · (3.2, 6.1) · (3.2, 6.3)
- Roll A · 0.3 s
- (1.6, 6.3) · (1.1, 5.9) · (1.4, 6.0) · (1.7, 6.2) · (1.2, 6.1)
- Roll B · 0.1 s
- (3.2, 6.4) · (2.5, 5.8) · (2.7, 6.0) · (3.0, 5.9) · (2.6, 5.9)
- Roll B · 0.3 s
- (1.3, 5.9) · (1.5, 6.4) · (1.2, 5.8) · (1.0, 6.2) · (1.5, 6.2)
- Roll C · 0.1 s
- (2.8, 6.7) · (3.5, 6.1) · (2.7, 6.2) · (3.1, 6.0) · (2.9, 6.5)
- Roll C · 0.3 s
- (3.0, 6.4) · (3.2, 6.1) · (3.4, 6.3) · (3.1, 6.0) · (2.8, 6.7)